Part Number Hot Search : 
60N10 6968D NCA005 2SK21 70412 16C55 HCS132MS H101CYDL
Product Description
Full Text Search
 

To Download KMT40-51515 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  77 1-800-526-2324 ? www.us.tdk-lambda.com/lp/ disclaimer: us.tdk-lambda.com/lp/legal.htm km series features ? small size and lightweight ? pc board mountable ? wide range input ? medical safety certi cations (4kvac input - output) ? class ii (no ground needed) ? high ef ciency 15-40w medical ac-dc pcb-mount power supplies model kms15 kmd15 kmt15 kms40 kmd40 kmt40 input voltage range - 90-264vac 47-440hz or 100-375vdc* inrush current limiting a 10 / 20a, cold start, 25c ambient (115 / 230vac) input current (115 / 230vac) ma 292 / 188ma 860 / 460ma recommended external fuse - 2a slow blow type 3.15a slow blow type temperature coef cient - 0.01%/c ripple and noise (pk-pk) mv 50mv or 1%, whichever is greater overcurrent protection - > 105%, hiccup mode, automatic recovery overvoltage protection % yes, zener diode clamp hold-up time (typical) ms 20ms 18ms enclosure leakage (240vac 63hz) ma 0.055 max 0.08 max (264vac 63hz) 0.06 max 0.085 max operating temperature c -25c to 70c, derate linearly to 50%(1) load from 50c to 70c. max case temperature 95c storage temperature c -40c to 100c humidity %rh 20% to 95% rh (non-condensing) cooling - convection, over temperature protected ~100c case temperature withstand voltage vac input to output: 4kvac (reinforced) (2 x mopps 3rd edition) immunity - en60601-1-2 safety agency certi cation - ul/csa/iec/en 60601-1, ansi/aami es60601-1, iec/en60950-1, ce mark conducted emi - en55011, en55022 class b en55011, en55022 class a switching frequency khz 132khz weight g 120 280 size (lxwxh) in 2.52 x 1.79 x 0.92? 3.5 x 2.5 x 1.06? mounting & case - pc board mountable. plastic resin berglass case (ul 94v-0) mtbf hrs 200,000 to 400,000 hours, model dependent warranty yrs 2 years speci cations (1) km15 derates linearly to 40% load key market segments & applications *safety certi ed for ac input only
78 1-800-526-2324 ? www.us.tdk-lambda.com/lp/ revision b7: jul 2015 km series for additional information, please visit us.tdk-lambda.com/lp/products/km-series.htm km15 outline drawings km40 outline drawings output minimum maximum output set line load voltage current current power accuracy regulation regulation (1) cross ef ciency model (v) (a) (a) (w) (%) (%) (%) regulation (%) single output kms15-3p3 v1 3.3v 0a 3.00a 9.9w 2% 0.5% 1% - 74% kms40-3p3 v1 3.3v 80ma 8.00a 26.4w 2% 0.5% 1% - 75% kms15-5 v1 5v 0a 3.00a 15w 2% 0.5% 1% - 78% kms40-5 v1 5v 80ma 8.00a 40w 2% 0.5% 1% - 79% kms15-9 v1 9v 0a 1.67a 15w 2% 0.5% 1% - 79% kms40-9 v1 9v 44ma 4.44a 40w 2% 0.5% 1% - 82% kms15-12 v1 12v 0a 1.25a 15w 2% 0.5% 1% - 81% kms40-12 v1 12v 33ma 3.33a 40w 2% 0.5% 1% - 83% kms15-15 v1 15v 0a 1.00a 15w 2% 0.5% 1% - 81% kms40-15 v1 15v 26.7ma 2.67a 40w 2% 0.5% 1% - 83% kms15-24 v1 24v 0a 0.62a 15w 2% 0.5% 1% - 83% kms40-24 v1 24v 16.7ma 1.67a 40w 2% 0.5% 1% - 83% dual output kmd15-55 v1 +5v 150ma 1.5a 2% 0.5% 1% 5% v2 -5v 150ma 1.5a 2% 0.5% 1% 5% kmd40-55 v1 +5v 400ma 4a 2% 0.5% 1% 5% v2 -5v 400ma 4a 2% 0.5% 1% 5% kmd40-512 v1 5v(2) 1250ma 5a 3% 0.5% 2% 1% v2 12v(2) 312ma 1.25a 5% 5.0% 6% 7% kmd40-524 v1 5v(2) 1250ma 5a 3% 0.5% 2% 1% v2 24v(2) 156ma 0.625a 5% 5.0% 6% 7% kmd15-1212 v1 +12v 62.5ma 0.625a 2% 0.5% 1% 3% v2 -12v 62.5ma 0.625a 2% 0.5% 1% 3% kmd40-1212 v1 +12v 166ma 1.66a 2% 0.5% 1% 5% v2 -12v 166ma 1.66a 2% 0.5% 1% 5% kmd15-1515 v1 +15v 50ma 0.5a 2% 0.5% 1% 3% v2 -15v 50ma 0.5a 2% 0.5% 1% 3% kmd40-1515 v1 +15v 133ma 1.33a 2% 0.5% 1% 5% v2 -15v 133ma 1.33a 2% 0.5% 1% 5% triple output kmt15-51212 v1 5v(3) 500ma 2a 2% 0.5% 1% 1% v2 +12v 50ma 0.2a 15w 3% 2.0% 5% 5% 78% v3 -12v 50ma 0.2a 3% 2.0% 5% 5% kmt40-51212 v1 5v(3) 1250ma 5a 3% 0.5% 3% 3% v2 +12v 150ma 0.6a 40w 5% 5.0% 7% 7% 80% v3 -12v 150ma 0.6a 5% 5.0% 7% 7% kmt15-51515 v1 5v(3) 500ma 2a 2% 0.5% 1% 1% v2 +15v 37.5ma 0.15a 15w 3% 2.0% 5% 5% 78% v3 -15v 37.5ma 0.15a 3% 2.0% 5% 5% KMT40-51515 v1 5v(3) 1250ma 5a 3% 0.5% 3% 3% v2 +15v 125ma 0.5a 40w 5% 5.0% 7% 7% 80% v3 -15v 125ma 0.5a 5% 5.0% 7% 7% 15w 40w 40w 40w 15w 40w 15w 40w 78% 79% 80% 80% 80% 83% 81% 81% output ratings (1) symmetrical loading, from minimum to maximum load (2) output v1 is isolated from output v2 (3) output v1 is isolated from outputs v2 & v3


▲Up To Search▲   

 
Price & Availability of KMT40-51515

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X